Header Ads

User Manual of Geekvape E100i Kit

 

1. Power On: Press the fire key 5 times within 2s to display the start up animation and enter the standby interface.

2. Power Off: Press the fire key 5 times within 2s to display the post shut down animation screen.

3. Power Setting: In the power working mode, click ”+” or ”-” to adjust the power, step 0.5W below 100W, step 1W above 100W, and cycle 5-100W. Press and hold the key to enter the quick adjustment mode. (the power values of smart, power and boosting modes are independent and do not affect each other).

4. Temperature Control: In the temperature control mode, click “+”or “-.” to adjust the temperature. The temperature steps into a cycle of 1C/5 T ,100℃~ 315℃ to 200 F ~ 600 F. Press and hold the key to enter the quick adjustment mode.

Degrees Celsius and Fahrenheit automatically switch when they are adjusted to the upper and lower limits of temperature.

5. Enter Settings: Press the fire key for 3 times within 2s to enter the setting state.

6. Exit Settings: Press and hold the fire key for 0.8s to confirm the change and exit the setting state (no operation in the setting state,and exit automatically after 5S).

7. Mode Setting

①Press the fire key for 3 times within 2s to enter the setting state;

②The cursor stays at the working mode in the upper left corner and press the “+” or”-” key;

③Optional working modes include: smart, power, boosting, tc-ni, tc-ti, tc-ss, tc-tcr and vpc. (after power on for the first time and restoring the factory settings, the default smart mode will be switched according to the above sequence).

8. TC Setting

①Press the fire key for 3 times within 2s to enter the setting state;

②Press the fire key to switch the cursor and stay in the wat parameter display column;

③Press the “+” or “-” key to adjust wat parameters, and long press the key to enter the quick adjustment mode.

9. Puff Clear

①Press the fire key for 3 times within 2s to enter the setting state;
②Press the fire key to switch the cursor and stay in the puff display column;
③Press “+” or “-” to clear the current value;
④Press “+” or “-” again to restore the current value.

10. TCR Setting

①Press the fire key for 3 times within 2s to enter the setting state;
②Press the fire key to switch the cursor and stay in the TCR parameter display column;
③Press the “+” or”-” key to adjust TCR parameters, and long press the key to enter the rapid adjustment mode.

11. VPC Setting

①Press the fire key for 3 times within 2s to enter the etting state;
②Press the fire key to switch the cursor to P power column;
③Press the “+” or”-” key to adjust the P1 power value, and long press the key to enter the quick adjustment mode.
④Continue to press the fire key to switch the cursor to the P2 power bar;
⑤Press the “+” or “-” key to adjust the P2 power value, and long press the key to enter the quick adjustment mode.
⑥Similarly, set P3, P4 and P5 power values.

12. Locked Or Unlocked: In the standby mode, push down the a-lock switch to enter the locking state, and the screen displays the locking icon. In the locking state, except for the on-off operation, other operations are invalid. Push the a-lock switch upward to release the locking state.

13. Tips And Protection

①The temperature of the electric cell is> 55℃ before output or>60℃ during output, and the equipment is overheated for 2 seconds; When the temperature of the cell is less than – 20℃ before the output, the equipment will give a low temperature prompt for 2 seconds;
②Atomizer resistance < 0.08ohm output short circuit prompt for 2seconds; ③Atomizer resistance > 3.5ohm high resistance prompt for2seconds;
④If the voltage of a single battery is less than 3.2V before output or less than 2.8V during output, the output will be stopped, and the low voltage prompt will be given for 2 seconds The main board temperature is> 65℃ before output or> 85℃ during output, and the equipment overheats for 2 seconds;
⑤If the atomizer is not connected, press the fire key and there is no atomizer prompt for 2 seconds;
⑥If a single smoking exceeds 10s, the output will be stopped and the timeout prompt will be given for 2 seconds;
⑦Push the a-lock switch to lock or unlock the prompt for 2 seconds;
⑧Operate the key in the locked state and press the prompt on the lock screen for 2 seconds.

14. Atomizer Identification

①In the standby interface, it will monitor whether the atomizer is replaced and update the latest resistance value of the atomizer;
②When a new atomizer is insertsed, the screen will jump to the old and new atomizer selection interface and prompt the user to select the old and new atomizers;
③Click ‘+’ to select the new atomizer and ‘-‘ to select the old atomizer;
④When the original atomizer is removed, the resistance value of the atomizer will be cleared automatically;
⑤In smart and boost modes, the resistance value is update directly without prompting for selection.

15. SMART Mode

①Resistance value of the atomizer, and the user can adjust the output power within the best power range through the adjustment key; In this mode, the dynamic screen is displayed (see UI for details)
②After the ignition output, the current gear power will be memorized. When the load is connected next time, the corresponding memory power will be adjusted. After power on again or factory seting is retored, the memory power will be retotet default power.

16. Boosting Mode

①The battery box matches the maximum output power according to the resistance value of the atomizer, and the user cannot adjust the output power,
②When staying in this interface, the dynamic screen will be displayed (see Ul for details).

17. Display: After the fire key is pressed for times to shut down,press the “+” and-” keys for 2S at the same time, and the current software version number information will be displayed on the screen.

18. Reset: After entering the version information interface, press the”fire” and”+” – “keys at the same time to restore the factory settings.

19. UI Setting: In the setting mode, press and hold the ‘+’ and ’-‘ keys simultaneously for 1 second to switch to the next topic.

20. Stealth Mode
①Press the fire key,’+’ and ‘- keys for two seconds at the same time to enter the stealth mode;
②In the same way, exit the steelth mode.

21. Screen Brightness Adjustment: In the standby interface, press and hold the fire key and ‘+ key for 1 second at the same time to display the brightness adjustment icon and step up the screen brightness by percentage. Press and hold the fire key and’· key at the same time to dim the screen brightness.

22. USB Upgrade Function: Factory side upgradeable.